Access Lift
Categories: Kunci Hotel ADEL, Security System
Description
Access Lift
Akses Lift
Elevator Controller
Adel Elevator Controller
Lift Controller
Access Lift yang biasa digunakan untuk Hotel, Gedung dan Apartment. Access lift Ini kami kategorikan sebagai Access Lift dengan Specific Floor, maksudnya jika tamu atau penghuni check-in atau tinggal di kamar 505 maka kartu access hanya bisa digunakan untuk lantai 5 sehingga tidak semua orang yang memegang kartu bisa menuju ke semua lantai yang ada. Hal ini dimaksudkan agar hotel atau apartment aman dari tamu-tamu yang tidak berkepentingan. Access Lift atau biasa disebut Elevator Controller dengan spesifikasi sebagai berikut:
Parameter:
|
Item |
Explanation |
Parameter |
Note |
|
Main Control Board Input Voltage |
Elevator Controller Main Control Board Input Voltage |
DC12V±10%/3.2A |
|
|
Operating Current |
MAX. Operating Current of Elevator Controller |
≤500mA |
|
|
Number of floors controlled |
A controller can control the number of floors |
16 floors |
A90:Maximum floor extension 255 D81:Maximum floor extension 79
|
|
Contact Resistance |
One contact on/off resistance |
On resistance<5Ω; off resistance>10MΩ; |
|
|
Contact Rating |
Contact can withstand the maximum current. |
AC277V 10A; AC125V 12A; |
|
|
Storage environment |
|
Temperature: -10℃~85℃; Humidity: 20%~90%R.H,non condensing
|
|
|
Operating environment |
|
Temperature: -10℃~60℃; Humidity: 20%~90%R.H,non condensing |
|
|
Communication Interface |
Communication between the main control board and reader |
RS 485 |
|
|
Communication Parameter |
RS485 Setting Parameter |
Communication Rate: 9600Bps Data Bits:8 Check: NON Stop Bit:1 |
|
|
Read Card Time |
The response time of normal operation after swiping card for elevator |
<0.5S |
|
|
Delay Time |
Elevator can be operated during the delay time. |
5S
|
|
|
Record Size |
Operating elevator record |
828 |
|
Principle and Structure
ADEL elevator controller consists of main control board、switching power supply、reader、card and other accessories。According to the settings in the hotel management software。Card in this system has master card、foreman card、maid card、floor card、guest card, variety cards with different floor permission.
The elevator controllers do not communication with central controller of elevator itself。There is no direct mutual control。It’s function is to control the elevator floor buttons。Therefore, all the original security features of the elevator itself is not affected。
Under normal circumstances, switching power supply、main control board are installed on the elevator car top, reader installed in the elevator car。Cardholder swipes card when using the elevator, the system selects specified floor by card privileges。
Wiring Diagram

Mifare card elevator controller wiring diagram
Installation Instruction
Reader PANEL CUT-OUT
Reader Outline

Installation Effect Drawing